AWWA standard for reduced-wall, resilient-seated gate valves by American National Standards Institute.; American Water Works

By American National Standards Institute.; American Water Works Association

Show description

Read or Download AWWA standard for reduced-wall, resilient-seated gate valves for water supply service PDF

Similar nonfiction_12 books

Cracking the GRE with 4 Practice Tests, 2014 Edition

THE PRINCETON overview will get effects. Get all of the prep you want to ace the GRE with four full-length perform checks, thorough GRE subject reports, and additional perform on-line. contained in the booklet: all of the perform & techniques you wish · 2 full-length perform checks with distinctive resolution reasons · specialist topic experiences for all GRE try themes · Drills for every try out section—Verbal Reasoning, Quantitative Reasoning, and the Essays · Key ideas for tackling textual content final touch, Numeric access, Quantitative comparability, and different query forms · sensible details & basic GRE suggestions  unique entry to extra perform and assets on-line · 2 extra full-length perform tests· immediate ranking studies for on-line exams · complete solution motives & unfastened functionality facts· step by step reasons for the hardest GRE questions · Downloadable research courses, grad college & software profiles, and searchable suggestion part, and extra

Tropical Natural Fibre Composites: Properties, Manufacture and Applications

This ebook covers the several features of tropical normal fibre composites in parts comparable to homes, layout and research, production innovations, fabric collection of kenaf, oil palm, sugar palm, pineapple leaf, coconut, sugarcane and banana dependent fibre composites. very important houses resembling mechanical and thermal of typical fibres in addition their composites are provided.

Extra info for AWWA standard for reduced-wall, resilient-seated gate valves for water supply service

Sample text

The valve box should be installed so as not to transmit loads or stress to the valve, valve stem, or piping system. The valve box should be centered over the operating nut of the valve with the box cover flush with the surface of the finished area or another level as directed by the purchaser. Valve boxes should be designed so that a traffic load on the top of the box is not transmitted to the valve stem or piping system. 3 Valves buried in unusually deep trenches have special provisions for operating the valve.

If the actuator has a torque-limiting device, it should be set below the values in Sec. 5. If there is no torque-limiting device, the recommended practice is to stop the power actuator three or four turns before the valve is fully opened or fully closed and complete the operation manually. Maintenance should be performed at the time a malfunction is discovered to avoid a return trip to the same valve or to prevent neglecting it altogether. A recording system should be adopted that provides a written record of valve location, condition, maintenance, and each subsequent inspection of the valve.

During outside storage, they should be protected from the weather, sunlight, ozone, and foreign materials. In colder climates where valves may be subject to freezing temperatures, it is absolutely essential to prevent water from collecting in the valves. Failure to do so may result in a cracked valve casting or deterioration of the resilient seat material. 5: INSTALLATION Instructions supplied by manufacturers should be reviewed in detail before valves are installed. At the job site prior to installation, each valve should be visually inspected and a n y foreign material in the interior portion of the valve should be removed.